Line 4: Line 4:
* hydraulic parameters of the heat exchangers, pipes, and check valves, represented at first level by <math display="inline">(C_dA)_{\mathrm{eff}}</math>;
* hydraulic parameters of the heat exchangers, pipes, and check valves, represented at first level by <math display="inline">(C_dA)_{\mathrm{eff}}</math>;
* thresholds <math display="inline">\Delta P_{\mathrm{open}}</math>, <math display="inline">\Delta P_{\mathrm{close}}</math>;
* thresholds <math display="inline">\Delta P_{\mathrm{open}}</math>, <math display="inline">\Delta P_{\mathrm{close}}</math>;
* kinematic targets <math display="inline">\Lambda_L^*</math>, <math display="inline">\Lambda_S^*</math>.
* position of each check valve upstream or downstream of its heat exchanger;
* kinematic reference levels <math display="inline">\Lambda_L^*</math>, <math display="inline">\Lambda_S^*</math>, when used.

Latest revision as of 19:02, 20 September 2026

Information about message (contribute)
This message has no documentation. If you know where or how this message is used, you can help other translators by adding documentation to this message.
Message definition (Thermodynamic and Mechanical Study)
* <math display="inline">V_{S,\min}</math>, <math display="inline">V_{S,\max}</math>, <math display="inline">V_{L,\min}</math>, <math display="inline">V_{L,\max}</math>;
* <math display="inline">V_i</math>, <math display="inline">V_o</math>;
* <math display="inline">(UA)_i</math>, <math display="inline">(UA)_o</math>;
* hydraulic parameters of the heat exchangers, pipes, and check valves, represented at first level by <math display="inline">(C_dA)_{\mathrm{eff}}</math>;
* thresholds <math display="inline">\Delta P_{\mathrm{open}}</math>, <math display="inline">\Delta P_{\mathrm{close}}</math>;
* position of each check valve upstream or downstream of its heat exchanger;
* kinematic reference levels <math display="inline">\Lambda_L^*</math>, <math display="inline">\Lambda_S^*</math>, when used.
  • VS,min, VS,max, VL,min, VL,max;
  • Vi, Vo;
  • (UA)i, (UA)o;
  • hydraulic parameters of the heat exchangers, pipes, and check valves, represented at first level by (CdA)eff;
  • thresholds ΔPopen, ΔPclose;
  • position of each check valve upstream or downstream of its heat exchanger;
  • kinematic reference levels ΛL∗, ΛS∗, when used.