Thermodynamic and Mechanical Study
1. Scope and method
This study describes the complete driven cycle of the Dada machine in symbolic form. The model couples prescribed kinematics of the two pistons, well-mixed gas volumes, 0D heat exchangers, passive check valves, and a generic compressible hydraulic closure model.
The cycle origin is set at the top position of the large cylinder, with:
The four gas volumes are:
S: small cylinder, directly associated with the cold heat exchangerC;L: large cylinder, directly associated with the hot heat exchangerH;C: cold heat exchanger, which absorbs heat from the cold reservoir;H: hot heat exchanger, which rejects heat to the hot reservoir.
The check valves allow H → S during Phase II and C → L during Phase IV.
The cycle comprises four phases:
- Phase I — check valves closed, nominally adiabatic: compression on the
L+Hside; - Phase II — heat exchange, nominally isothermal: transfer
L → H → S, with heat rejection on the hot side; - Phase III — check valves closed, nominally adiabatic: expansion on the
S+Cside; - Phase IV — heat exchange, nominally isothermal: transfer
S → C → L, with heat absorption on the cold side.
The terms nominally adiabatic and nominally isothermal describe the objective of the cycle. They do not constitute exact thermodynamic constraints: temperatures are calculated from the balances, the heat exchangers remain coupled to their reservoirs, and the low-displacement regions of the pistons are not assumed to be perfectly stationary.
1.1 First-level assumptions
The model is based on the following assumptions:
- single-phase, ideal and calorically perfect gas;
- constant properties , , , , with and ;
- each gas volume is uniform and well mixed;
- gas kinetic and potential energies are neglected in the 0D balances;
- fixed heat-exchanger volumes;
- prescribed piston kinematics;
- no mechanical friction in the thermodynamic model;
- heat exchange represented by an overall conductance ;
- passive check valves controlled by the pressure difference.
2. Notation and conventions
2.1 Geometry and kinematics
For :
The swept volume is:
The thermodynamic volumes prescribed by the mechanism are:
with their signed derivatives:
If the crank rotates at constant angular speed :
When only the absolute value of the volumetric speed is useful:
A quasi-stationary region denotes an interval in which the displacement or remains small compared with the transfer phases. This region corresponds to the “plateau” of the kinematic optimization, without assuming exactly.
2.2 Kinematic closure fraction
To describe the normalized closure of a cylinder:
Thus corresponds to maximum volume and to minimum volume. The values and are nominal kinematic targets at the transitions. The value actually reached at a check-valve event is:
The physical transitions remain determined by the pressures; is therefore not an imposed opening condition.
2.3 Thermodynamic variables
For each volume :
The complete state vector is chosen as:
Temperatures and pressures are derived from it:
The volumes and are prescribed by the kinematics and are not independent thermodynamic state variables. The volumes and are constant.
2.4 Energy sign convention
Heat is positive when it is received by the gas. Work is positive when the gas delivers work:
For the intended refrigeration operation:
3. Thermal closure and validity domain
3.1 Exchange with the thermal reservoirs
For a heat exchanger :
is the temperature of the external thermal reservoir, prescribed and constant in the base model. is the mean 0D temperature of the gas in the heat exchanger. represents the overall thermal conductance, which may combine convection, wall conduction, and contact resistances.
Cold side:
In refrigeration operation, gives .
Hot side:
In refrigeration operation, gives .
A nominally isothermal phase therefore does not mean : a finite temperature difference is required to transfer finite thermal power when is finite.
An indicator of isothermal quality may be defined over a given phase by:
3.2 Thermophysical validity domain
The base model assumes:
Validity must be checked a posteriori over the entire cycle, notably through:
and through small variations of the thermophysical properties, for example:
The working fluid must remain single-phase and gaseous, and sufficiently far from any condensation or phase transition throughout the domain traversed.
If these criteria become insufficient, an extension may use , , , or a real-gas equation of state without changing the general architecture of the mass and energy balances.
4. Reduced formulation of a quasi pressure-equalized pair
When a cylinder and its heat exchanger are connected by a very low-resistance internal path, the approximation
may be used. It is acceptable if:
A low internal Mach number provides an additional check:
but it is not sufficient on its own to guarantee pressure equalization.
4.1 Closed-pair case
For a closed pair, with fixed and :
When :
4.2 Internal redistribution flow rate
The internal flow rate is defined as positive from cylinder → heat exchanger. Let:
The flow carries the enthalpy of the upstream state:
The heat-exchanger temperature evolves according to:
4.3 Open receiving pair
During an active phase, the external flow physically enters the receiving cylinder, not directly its associated heat exchanger. If enters the cylinder at temperature :
The masses satisfy:
and therefore:
The closed case is obtained immediately with .
5. Hydraulic closure
5.1 Generic formulation
Any hydraulic connection is described by a generic law:
and respectively denote the upstream and downstream states. The transported enthalpy is that of the upstream state:
For a bidirectional connection, the upstream state is determined by the actual direction of the pressure gradient. For a check valve, reverse flow is prohibited.
5.2 First-level closure using a compressible orifice
A first approximation consists in using an effective hydraulic area:
which represents the overall ease of gas flow through the actual connection.
With:
the unchoked flow rate, for , is:
For :
This closure is not essential to the model: it may later be replaced by a law that more faithfully represents the pressure losses of a real heat exchanger, pipe, or check valve.
6. Complete thermodynamic cycle
6.1 Phase I — check valves closed, nominally adiabatic: compression on the L side
Both check valves are closed. The L+H and S+C pairs are closed. The L+H side is nominally compressed; the motion of the small piston remains that provided by the actual kinematics.
For L+H:
For S+C:
The internal redistribution and temperature equations of §4 apply to both pairs.
The transition to Phase II occurs when the H → S check valve satisfies its opening condition.
6.2 Phase II — heat exchange, nominally isothermal: L → H → S
The gas leaves L, passes through the hot heat exchanger H, where it rejects heat, crosses the H → S check valve, and then enters the receiving cylinder S. The S+C pair remains quasi pressure-equalized if the criterion is satisfied.
6.2.1 Donor cylinder L
The fundamental balance is:
The kinematics are designed to maintain an outflow from the donor cylinder. In this case, the analytical solution is:
and:
One also obtains:
and the specific entropy of the remaining gas satisfies under these assumptions. If reverse flow occurs despite the kinematic design, the analytical solution is no longer applicable and the complete open-system balance in must be used.
6.2.2 Hot heat exchanger H
Mass conservation:
Fundamental energy balance:
In expanded form:
The flow rates are determined by the hydraulic laws:
6.2.3 Receiving pair S+C
The flow from H enters S. The pair pressure satisfies:
The internal redistribution equations of §4 remain unchanged: the external flow acts on heat exchanger C indirectly through the evolution of the pair pressure.
The transition to Phase III is the closing event of the H → S check valve.
6.3 Phase III — check valves closed, nominally adiabatic: expansion on the S side
Both check valves are closed. The S+C pair expands nominally; the L+H pair also remains closed. Neither piston is assumed to be strictly stationary.
For S+C:
For L+H:
The transition to Phase IV occurs when the C → L check valve satisfies its opening condition.
6.4 Phase IV — heat exchange, nominally isothermal: S → C → L
The gas leaves S, passes through the cold heat exchanger C, where it receives heat from the cold reservoir, crosses the C → L check valve, and then enters the receiving cylinder L. The L+H pair remains quasi pressure-equalized if the criterion is satisfied.
6.4.1 Donor cylinder S
The fundamental balance is:
For outflow guaranteed by the kinematic design:
and:
Reverse flow requires returning to the complete open-system balance in .
6.4.2 Cold heat exchanger C
The fundamental energy balance is:
In expanded form:
The flow rates are determined by:
6.4.3 Receiving pair L+H
The flow from C enters L. The pair pressure satisfies:
Closing the C → L check valve returns the system to Phase I. Geometric closure of the pistons alone is not sufficient to guarantee thermodynamic closure of the cycle.
7. Physical transitions of the check valves
For a check valve oriented from upstream to downstream :
with hysteresis, if present:
An opening or closing event changes the hydraulic topology and therefore the active equations; it does not cause any instantaneous jump in the thermodynamic state. For each volume:
For an ideal gas:
There is therefore no instantaneous pressure equalization when a check valve opens.
The values serve as kinematic design targets; the values actually observed at the transitions are .
8. Work, heat, and coefficient of performance
The instantaneous work delivered by the gas on the two pistons is calculated during all phases:
and denote the thermodynamic pressure effectively applied to the gas in each cylinder according to the phase topology: pair pressure when the cylinder belongs to a quasi pressure-equalized pair, and its own pressure when it is a hydraulically isolated donor.
The net work over the cycle is:
The exchanged heats are:
In periodic steady operation:
and the first law gives:
The refrigeration COP is:
The heat-pump COP is:
The signs , , and provide checks of the intended refrigeration regime.
The thermodynamic force exerted by the gas on a piston face may be written . Net mechanical force, inertia, and friction belong to the subsequent mechanical sizing stage.
9. Gas charge and periodic regime
The total amount of enclosed gas is a physical parameter:
It may be imposed directly or defined experimentally by a charging pressure and temperature. The chosen reference configuration is that at , with the large cylinder at maximum volume. If all volumes communicate and are in uniform equilibrium during charging:
and define the amount of gas charged; they are not conditions that the periodic cycle must recover.
The established periodic regime is a solution of the system such that, between two successive passages through the top position of the large cylinder with the same kinematic direction:
Geometric periodicity alone:
is not sufficient to guarantee thermodynamic periodicity.
The numerical state used to initialize a calculation may be approximate; it must not be confused with a physical parameter of the machine. The future solver may search for the periodic fixed point by successive cycles, a shooting method, or a Newton method.
10. Parameters, design data, and results
10.1 Prescribed data
- working fluid and reference properties , , , ;
- reservoir temperatures , ;
- total charge , or equivalently in the charging configuration defined in §9;
- kinematics , , and, where relevant, .
10.2 Design parameters
- , , , ;
- , ;
- , ;
- hydraulic parameters of the heat exchangers, pipes, and check valves, represented at first level by ;
- thresholds , ;
- kinematic targets , .
10.3 Calculated variables and results
- , , , ;
- internal and external mass flow rates;
- , , , ;
- , , ;
- pressure, temperature, and flow-rate extrema;
- actual check-valve events and ;
- isothermal quality ;
- validity criteria , , , and property variations.
11. Global conservation checks
11.1 Mass conservation
The solver must satisfy:
A useful numerical residual is:
11.2 Global energy conservation
Whatever the phase, the internal mass and enthalpy fluxes must cancel when the balances of all volumes are summed. The global balance must reduce to:
A cumulative energy residual may be defined by:
The solver must keep and close to zero to the expected numerical accuracy.
Appendix A — Symbolic derivations and validated checks
A.1 Pressure equation for a closed pair
For a cylinder + heat-exchanger pair at quasi-uniform pressure:
The first law gives:
with:
Differentiating :
Hence:
If :
then:
A.2 Internal flow rate of the pair
For the heat exchanger alone, at fixed volume:
Therefore:
Using :
This recovers the definition of the numerator and the selection of the upstream temperature according to the sign of the flow rate.
A.3 Evolution of the heat-exchanger temperature within a pair
For a fixed volume:
Differentiating:
With :
This relation follows solely from mass conservation and the equation of state; it is valid for both flow directions.
A.4 Open receiving pair
For a pair receiving into its cylinder:
With :
The local mass balance:
immediately gives:
A.5 Analytical solution for the adiabatic donor cylinder
For an adiabatic, well-mixed cylinder with outflow only:
and:
Expanding:
thus:
With and :
After integration:
Then, using :
and:
Under these assumptions, the specific entropy of the remaining gas is constant: . The total entropy of the gas contained in the cylinder is not constant because its mass varies.
A.6 Active heat exchanger: expanded balance
Fundamental balance:
Expanding the left-hand side and using:
one obtains:
Limiting checks:
- with no flow, the equation recovers the thermal relaxation of a closed volume;
- with equal steady inlet/outlet flow rates, it recovers ;
- if and , the net contribution of the flow to vanishes.
A.7 Global mass test during an active phase
For Phase II:
Summing:
Phase IV gives exactly the same result by symmetry.
A.8 Global energy test during an active phase
For Phase II:
The internal enthalpy fluxes cancel exactly:
What remains is:
Phase IV provides the symmetric relation. In the closed phases, the same structure follows directly from summing the balances of the two pairs. Hence, for any phase:
Integrated over a periodic cycle, this relation gives:
A.9 Continuity at transitions
At the instant of a check-valve event, no finite mass or energy can be transferred in zero time. The conserved variables and geometry are therefore continuous:
For an ideal gas:
which implies:
The event only creates a change in hydraulic topology and in the active system of equations.