- Phase I — check valves closed, nominally adiabatic: compression on the
L+Hside; - Phase II — heat exchange, nominally isothermal: transfer
L → H → S, with heat rejection on the hot side; - Phase III — check valves closed, nominally adiabatic: expansion on the
S+Cside; - Phase IV — heat exchange, nominally isothermal: transfer
S → C → L, with heat absorption on the cold side.