Translations:Thermodynamic and Mechanical Study/575/en

From dada-engine.org

No closed-pair topology is imposed. A check valve may remain open during part of the compression, and gas may continue to move through the hydraulic network. In particular, a cylinder approaching its minimum volume may transfer its remaining gas toward the other cylinder. Heat transfer through Hi and Ho also remains active.